Title: Comparison of intracoronary adenosine and isosorbide dinitrate on no-reflow/slow flow during rotational atherectomy
Author(s): T-P. Tsao , S-M. Cheng , C-C. Cheng , S-P. Yang
Journal: Acta Cardiologica
Volume: 64    Issue: 2   Date: 2009   
Pages: 225-230
DOI: 10.2143/AC.64.2.2036142

Abstract :
Objective — To compare the effect of intracoronary adenosine and isosorbide dinitrate (ISDN) on no-reflow/slow flow during high-speed rotational atherectomy (HSRA) in patients with complex coronary artery disease (CAD).
Methods and results — Medical records from consecutive patients diagnosed with complex CAD between November 2002 and March 2006 who underwent HSRA at the Tri-Service General Hospital, National Defence Medical Centre in Taipei, Taiwan, were included in this study. Patients in the adenosine group (n = 32) received a 50 mg intracoronary adenosine bolus prior to the initiation of burr rotation and during each ablation. Patients in the ISDN group (n = 58) received a 0.5 mg intracoronary ISDN bolus at comparable time points. Angiographic success was achieved in 100% of patients in the adenosine group and 98.3% (57/58) in the ISDN group. The procedural success rates were 96.9% (31/32) in the adenosine group and 89.7% (52/58) in the ISDN group. One patient (3.1%) from the adenosine group and six patients (10.3%) from the ISDN group experienced no-reflow/slow flow (P = 0.414). No in-hospital mortality occurred and target vessel revascularization was unnecessary.
Conclusions — Intracoronary administration of either adenosine or ISDN during HSRA appears safe and administration of either agent may be effective in decreasing the incidence of no-reflow/slow flow during HSRA. Further large, prospective, randomized, placebo-controlled trials are required.